Fluke 15B MAX Economical Digital Multimeter
Fluke 15B MAX builds on the classic design of the 15B+ instrument and adds further improved functions: A simple interface to wake the meter from sleep mode by activating any button, test leads with fine probes that help electricians and electronics R&D personnel take accurate measurements.
Key features
- Audible and visual warning of incorrect connection
- Test leads with fine tips for testing printed circuit boards
- A simple interface to wake the meter from sleep mode by activating any button
- Voltage: 6000 – count reading
- Capacitance range: 2000uF
- Safety class: CATIII 600V
| Specifications | ||||
|---|---|---|---|---|
| Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity of 0 % to 75 %. Accuracy specifications take the form: ± ([% of reading] + [number of least significant digits]). | ||||
| Function | Range | Resolution | Accuracy | |
| 15B MAX | 17B MAX | |||
| AC voltage (40 Hz to 500 Hz) 1 | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
1.0 % + 3 | 1.0 % + 3 |
| AC millivolts | 600,0 mV | 0,1 mV | 3.0 % + 3 | 3.0 % + 3 |
| DC volts | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.5 % + 3 | 0.5 % + 3 |
| DC millivolts | 600,0 mV | 0,1 mV | 1.0 % + 10 | 1.0 % + 10 |
| AC current μA (40 Hz to 400 Hz) 2 | 400,0 μA 4000 μA |
0,1 μA 1 μA |
1.5 % + 3 | 1.5 % + 3 |
| AC current mA (40 Hz to 400 Hz) 2 | 40,00 mA 400,0 mA |
0,01 mA 0,1 mA |
1.5 % + 3 | 1.5 % + 3 |
| AC current A (40 Hz to 400 Hz) 2 | 4 000 A 10:00 A |
0,001 A 0,01 A |
1.5 % + 3 | 1.5 % + 3 |
| DC current μA 2 | 400,0 μA 4000 μA |
0,1 μA 1 μA |
1.5 % + 3 | 1.5 % + 3 |
| DC current mA 2 | 40,00 mA 400,0 mA |
0,01 mA 0,1 mA |
1.5 % + 3 | 1.5 % + 3 |
| DC current A 2 | 4 000 A 10:00 A |
0,001 A 0,01 A |
1.5 % + 3 | 1.5 % + 3 |
| Diode test 3 | 2.000 V | 0.001 V | 10% | 10% |
| Temperature 4 | 50,0 °C to 400,0 °C 0 °C to 50,0 °C -55,0 °C to 0 °C |
0,1 °C | NA | 2 % + 1 °C 2 °C 9 % + 2 °C |
| Resistance (ohms) 5 | 400,0 Ohms 4.000 kΩ 40.00 kΩ 400.0 kΩ 4 000 MΩ 40,00 MΩ |
0,1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0,001 MΩ 0,01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
| Capacitance 6 | 40,00 nF 400,0 nF 4 000 μF 40,00 μF 400,0 μF 2000 μF |
0,01 nF 0,1 nF 0,001 μF 0,01 μF 0,1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
| Frequency 1 (10 Hz to 100 kHz) | 50,00 Hz 500,0 Hz 5000 kHz 50,00 kHz 100,0 kHz |
0,01 Hz 0,1 Hz 0,001 kHz 0,01 kHz 0,1 kHz |
NA | 0.1 % + 3 |
| Duty cycle 1 | 1 % to 99 % | 0.10% | NA | 1 % typical 7 |
| Continuity threshold | — | — | 70Ω | 70Ω |
| Backlight | — | — | Yes | Yes |
| 1 All AC, Hz and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2 Typical burden voltage: DC/AC current µA: 100 µV / µA; DC/AC current mA: 2 mV/mA; DC/AC current A: 0.03 V/A 3 Open-circuit test voltage is typically 2.0 V and short-circuit current <0.6 mA 4 Use a type K thermocouple 5 Typical open-circuit test voltage is 0.54 V, maximum short-circuit current is 1.8 mA 6 Specifications do not include errors caused by test lead capacitance and the lower capacitance limit (may be up to 1.5 nF in the 40 nF range). 7 Typical means the frequency is 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %. |
||||
| Input characteristics | ||||
|---|---|---|---|---|
| Function | Overload protection | Input impedance (nominal) | Common mode rejection ratio | Normal mode rejection ratio |
| AC voltage | 1000 V 1 | >10 MΩ, <100 pF | >60 dB at 50 Hz or 60 Hz | — |
| AC millivolts | 1000 V 1 | >1 MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | — |
| DC volts | 1000 V 1 | >10 MΩ, <100 pF | >100 dB at 50 Hz or 60 Hz | >60 dB at 50 Hz or 60 Hz |
| DC millivolts | 1000 V 1 | >1 MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | — |
| 1 10 6 V Hz max | ||||
| General specifications | |
| Maximum voltage between any terminal and ground | 600 V |
| Maximum voltage difference between the V and COM terminals | 1000V |
| Display (LCD) | 6000 counts, update 3/s |
| Battery type | 2 AA, IEC LR6 |
| Battery life | 500 hours minimum |
| Temperature | Operating 0 °C to 40 °C; Storage -30 °C to 60 °C |
| Relative humidity | Operating humidity Non-condensing (<10 °C); < 90 % RH at 10 °C to 30 °C; < 75 % RH at 30 °C to 40 °C |
| Operating humidity, 40 MΩ range | < 80 % RH at 10 °C to 30 °C; < 70 % RH at 30 °C to 40 °C |
| Altitude | Operating 2000 m; Storage 12000 m |
| Temperature coefficient | 0.1 X (specified accuracy) / °C (<18 °C or >28 °C) |
| Current input fusing | 440 mA, 1000 V, fast-blow, use only Fluke specified parts. 11 A, 1000 V, fast-blow, use only parts specified by Fluke |
| Size (HxWxD) | 183 mm x 91 mm x 49.5 mm |
| Weight | 455 g |
| Ingress protection | IP40 |
| Safety | IEC 61010-1, IEC61010-2-030: CAT III 600 V, pollution degree 2 |
| Electromagnetic environment | IEC 61326-1: Portable |
| Electromagnetic compatibility (EMC) | Applies only in Korea |
Class A device (equipment for industrial broadcasting and communication) 1
1 The equipment meets the requirements for industrial equipment with electromagnetic waves, and the seller or user should take note of this. This equipment is intended for use in a commercial environment and not for use in households.